Thyroid Biopsy Ultrasound Training Model
Thyroid Biopsy Ultrasound Training Model – Blue Phantom thyroid ultrasound fine needle biopsy training model allows users to develop and practice the skills necessary to gain proficiency in using ultrasound for imaging and guiding thyroid fine needle biopsy procedures.
Using Blue Phantom simulated human tissue, this very realistic and ultra-durable thyroid biopsy ultrasound training model is excellent for training clinicians in the psychomotor skills associated with ultrasound guided fine needle biopsies of the thyroid gland. These ultrasound imaging skills include
- Using ultrasound system controls
- Transducer positioning and movement
- Recognition of thyroid and surrounding structural anatomy
- Identification of a variety of masses present in the thyroid gland
- Using ultrasound system calculation packages
- Using ultrasound to target the lesions for fine needle biopsies
Learn to use ultrasound to identify thyroid pathology and target lesions for fine needle biopsies.
Our highly realistic ultrasound training model contains the thyroid, focal lesions suitable for fine needle biopsy, and pertinent surrounding anatomical structures. The anatomical structure contained within the thyroid ultrasound training model include:
- Left and right lobes of the thyroid gland
- Isthmus
- Multinodular goiter
- Multiple masses of varying sonographic appearances
- Trachea
- Esophagus
- Carotid arteries
- Internal jugular veins
Multiple simple and complex masses with a variety of sonographic appearances are present in the model including
- Hypoechoic
- Echogenic
- Echolucent with an echogenic rim
- Echogenic with a echolucent rim
BENEFITS
- This training phantom is constructed using Blue Phantom’s patented ultra-durable tissue. It’s extremely realistic in ultrasound imaging characteristics and feels like real human tissue. The masses in this soft tissue biopsy model can be accessed with needles and fluid can be injected into the model to verify needle tip location. Fluids are automatically expelled so that the model can be used repeatedly for training.
- We recommend that you utilize 18 – 21 gauge sharp, unbent needles during your training to maximize the self healing and ultra-durable performance of training model.
- While you are able to perform core biopsies and actually remove tissue from the tumors in the model, do this knowing that each mass can only withstand core biopsy until the lesion is destroyed which will require that you then move on to another mass located in the training model.
This thyroid ultrasound trainer will perform well using any ultrasound imaging system configured with the appropriate transducer (recommended ultrasound transducer; high frequency linear array ultrasound probe 7.5 – 15 MHz).
Our uncompromising quality allows clinicians to utilize the model and repeatedly practice the procedure without the high costs of replacing disposable parts.
This ultrasound phantom model is excellent for specialties including
- Thyroid surgery
- Surgical training programs
- Endocrinology training programs
- Radiology training programs
- Ultrasound training programs
- Simulation centers
- Surgical skills centers
- Medical education facilities
- Ultrasound manufacturers for ultrasound education and demonstrations.
Dimensions: 8” x 5” x 6” (20cm x 13cm x 15cm) (L x W x H)
Weight: 5.0 lbs. (2.3 Kg.)